128. High Voltage Feedback Tuning
One of the challenges associated with ultra- high voltage systems used
in plasma measurement applications is achieving stepping speed with high
accuracy settling (typically 14 –bits) over a voltage range from 0 volts
up to +/-15 kV. Battel Engineering has developed proprietary precision
high voltage resistor designs incorporating feed-forward delay-line
tuning to speed up feedback system response. |